4.5kw Underslung constant voltage regulated cum 2.4kW emergency battery charger with integrated SMPS Technology.
COMPLIANT STANDARDS:
IEC:60571, IEC:61000, IEC:61373, IEC60529, IEC:60310, IEC:61071
Input Voltage |
415 V ± 15%, 3-phase, 50 Hz ± 3% |
Output Voltage |
110V to 135 V DC (settable with the help of Key pad) |
Output current |
35A |
Battery charging current |
10A to 15A (settable with the help of Key pad) |
Other Loads |
20A |
Type & Ah rating of batteries |
Lead acid, 70 / 120 Ah (both flooded and VRLA) |
The Emergency Battery Chargers (EBC) |
|
Input Voltage |
240 V ± 15%, 1-phase, 50 Hz ± 3% |
Output voltage |
110 V ± 5% V DC |
Output current |
22A |
Output Power |
2.5 KW (Max.) |
The Battery Charger is used for DC load and Battery charging requirements for both AC and Non AC coaches. For redundancy it incorporates Emergency Battery Charger of 2.5 kW (for critical loads)