Highest System Voltage (Um) |
36 kV |
Test Voltage / Insulation Level (IL) |
75kV /170 kVp |
Ratio |
25000 / 200 Volt |
Rated Primary Voltage (Input Voltage) |
25 kV |
Rated Secondary Voltage (Output Voltage) |
200 Volt |
Burden |
30 VA |
Accuracy Class |
1.0 |
Voltage Factor (VF) |
1.2 Cont. / 1.5 for 30 Sec. |
Frequency |
50 / 60 Hz |
Creepage distance |
≥1090 mm |
Weight |
~80kg |
Compliance Standard |
IEC 61869 – 3 & EN 50152-3-3 |
Autometers Alliance Ltd offers 36kV Single pole magnetic Primary Voltage Transformer (PVT). It is designed with cast resin insulation with special type of pressure release system on the top of PVT which acts as burst proof system. It is design to meet all requirements of IEC 61869-3 & EN 50152 -3-3 standard and suitable to use on the roof of locomotives and outdoor application.