The product is developed for feeding auxiliary power to WAP5 / WAP7 / WAG9, WAG9H three phase locomotives for Indian Railways.
Compliant Standards: IEC 61287-1, IEC 60571, IEC 60310, IEC 61373 and IEC61375.
| Factors | Values |
|---|---|
| Minimum voltage | 760V, 50Hz±8% |
| Nominal voltage | 1000V, 50Hz±8% |
| Maximum Voltage | 1240V, 50Hz±8% |
| Factors | Values |
|---|---|
| AC Output | |
| Output Power | 3 ×130kVA |
| Voltage | 415V±5% (L-L) |
| Frequency | Controlled with nominal as 50Hz±3% |
| Waveform | Sine Wave |
| DC Output | |
| Voltage | DC110V±5% |
| Current | 80A |
| Factors | Values |
|---|---|
| Operating ambient temperature | 0 to 70 °C |
| Cooling | Forced air cooling for power cubicle |
| Control voltage | Nominal (77 to 137.5V dc) |
| Mounting | Onboard floor mounting |
| Weight Cubicle – 1 | ~700Kg |
| Weight Cubicle – 2 | ~1200Kg |
| Size of Cubicle – 1 | 1160 × 1020 × 1860 (L × D × H) |
| Size of Cubicle – 2 | 1520 × 1020 × 1860 (L × D × H) |
| Cubicle | IP54 for electronics and semiconductor |
The unit is put on board on three phase locomotive WAP5 / WAP7 / WAG9 / WAP9H. This is used to provide stabilized 3 phase sine wave voltage for safe and reliable operation of auxiliary motors and load. This also feeds DC load and battery charging.