BATTERY CHARGER 30 KWPRE-COOLING

BATTERY CHARGER 30 KWPRE-COOLING

Pre-cooling Unit Cum Charger IGBT based front end 30kW. The DSP based system works in four different modes to meet the requirement of SGAC coaches for Indian Railways.

Compliant Standards: IEC 60571, IEC 61000, IEC 61373.

 

  • State of the art DSP based system.
  • IGBT based rectifier to obtain input power factor close to Unity (0.99).
  • Low noise level smaller than 65 dB.
  • Very low voltage and current ripples smaller than 2%.
  • Facility to receive data via RS 232 communication on laptops for online data monitoring.
  • With onboard display unit to change the working mode and check the status of unit.
  • Capability to charge battery in constant voltage as well as constant current mode for different type of batteries (VRLA and LMLA with different current hour ratings).
BATTERY CHARGER 30 KWPRE-COOLING

Technical Specifications

A. Input

Factors Values
Nominal Voltage 415V ± 15%, 3-Phase AC
Frequency 50Hz ± 3%
Power Factor 0.99 (At Rated Current)

B. Output

Factors Values
Output Power 30kW maximum
DC Output Voltage 100 - 155 VDC
DC Output Current 220A
Operating Modes System works either in constant voltage or constant current mode while charging the Battery exclusively. In pre-cooling mode unit works as constant voltage. Modes selections are with external keyboard.

C. General

Factors Values
Operating ambient temperature 5°C to +55°C
Cooling Natural Cooled
Control Voltage Self Generated from input Power
Mounting: Cubicle – 1 Under slung
Mounting: Cubicle – 2 On-board Mounting in Coaches
Weight ≈ 350kg

 

Applications

The product is for under-slung fitment in self generating air conditioned coaches primarily for precooling the air conditioned coaches at the yard / station and charging the batteries (VRLA or LMLA fitted in Coaches).

Our Clients